Sample Submission Guidelines
General Instructions
Please
contact Dr. Sharma (uwyosif@uwyo.edu;
307-766-5021) before sending samples. All samples should be submitted with a
sample list and each sample should be labeled with a clearly defined
sample identification number. Each new job will be assigned a job number and
samples will be analyzed in the order they are submitted. Investigators should
send contact details of the person to whom the invoice should be sent. Please
fill in the
routing sheet
at time of sample submission. For job codes and types of analysis refer to
the
sample price list attachment. For isotopically
enriched samples please enquire beforehand; we do not accept samples that have more than 1% atomic enrichment.
Water
samples for δ18O and δ2H analysis
All
water samples submitted for analysis must be free of particulates. Samples must
be shipped in submitted in air tight vials with no head space. To avoid leakage
during transport you can wrap parafilm (www.parafilm.com) around the lid of the vial. For small
sample amounts use appropriate small sized conical bottom vials. If you ship
extracted water samples in glass tubes and need part of your samples to be saved
please provide us with appropriate vials.
Required
sample size:
50 to 500 microlitres
Carbonates δ13C+ δ18O analysis
Carbonate samples must be ground, homogenized and well mixed.
Required
sample size:
50 to 400ug of carbon/oxygen in sample
Gas δ13C + δ18O analysis
Samples
have to submitted in airtight 12 ml Labco vials
(http://www.labco.co.uk/usaandcanada/breathtest.htm#vials).
Required sample size:
CO2 conc. within 400 to 8000 ppm range
Solid Samples for δ13C / δ15N
/ δ18O / δ2H analysis
Samples
should be thoroughly dried, ground and well mixed. Samples pretreated with acids
need to be given least 5-8 rinses with distilled water to get rid of all the
acid in the sample. We can load your natural abundance samples ($1/sample). If
you have enriched samples or decide to load your natural abundance samples
yourselves please use 96 well plastic trays. Samples have to be loaded according
to the tray loading template.
Please leave the well number marked for lab standards empty.
Load samples in 3.5x5 mm/4x6 mm/5x9 mm tin or silver
capsules. You can order the capsules from
Costech. Try to
use the smallest capsule size that will hold the sample with no
leakage.
- Use tin capsules for δ13C / δ15N analysis
- Use silver
capsules for δ18O / δ2H analysis
Keep the working area, weighing table and spatula and forceps
very clean. Wipe the forceps and spatulas with Kimwipe
in-between subsequent samples. Capsules should be folded and
crushed into a cube or ball without any protruding wings or
sample. Samples that are flat or have protrusions tend to
get stuck in the sample carousel. For elemental C and N analysis
the same sample loading procedure should be followed.
Also, please ensure that no sample is leaking from the tin.
Required
sample size:
If you
are shipping the samples, special precautions need to be taken so please contact
Dr. Sharma at
uwyosif@uwyo.edu (307-766-5021).
|